TrueGrid logo

A Mesh Generator and Pre-Processor for
FEA and CFD Analysis

Release Notes for TrueGrid®
Version 3.1.1, April 1, 2015


1. A significant bug was fixed where element sets were corrupted when formed in the part phase and where block boundaries were used in the same part.

2. The mea/meai command in the part phase and the measure command in the merge phase reports the mean and the standard deviation of any measurement of mesh quality.

Four new automatic parameters are now availble after measuring the quality of the mesh. They are:

i. %minmea which will have the value of the minimum measure of the latest mesh quality measure.
ii. %maxmea which will have the value of the maximum measure of the latest mesh quality measure.
iii. %mean which will have the mean of the distribution of the measurement of the latest mesh quality measure.
iv. %standev which will have the standard deviation of the distribution of the measurement of the latest mesh quality measure.